{"id":235,"date":"2024-12-23T07:35:19","date_gmt":"2024-12-23T07:35:19","guid":{"rendered":"https:\/\/www.qrngua.website\/?p=235"},"modified":"2024-12-23T07:36:51","modified_gmt":"2024-12-23T07:36:51","slug":"the-results-of-pilot-operation-of-the-subsystem-of-universaltime-provision-for-military-consumers-based-on-the-precisetime-servers-microsemi-time-provider-4100","status":"publish","type":"post","link":"https:\/\/www.qrngua.website\/?p=235","title":{"rendered":"The results of pilot operation of the subsystem of universaltime provision for military consumers based on the precisetime servers Microsemi Time Provider 4100"},"content":{"rendered":"\n<p>As part of the operation of the military segment of the Service of Universal Time and Reference Frequencies, the<br>results of the pilot operation of the subsystem for providing universal time for military consumers are presented, which is<br>built on the basis of the national measurement standard of time and frequency, the output standard of the Armed Forces<br>of Ukraine of time and frequency using precise time servers (Microsemi Time Provider 4100) and fiber-optic technologies<br>for transmitting time synchronization signals via PTP and NTP protocols over packet data networks \u2013 Ethernet. Studies have confirmed the possibility of transmitting reference signals of time and frequency synchronization using<br>modern digital and fiber-optic technologies from the national measurement standard of time and frequency to the reference<br>standard of the units of time and frequency of the Armed Forces of Ukraine with the root mean square deviation (RMS)<br>of error not exceeding 30 ns.<br>RMS from the mean value of the reference signal of frequency 1 \u0420\u0420S of the slave server of the communication center<br>(Kyiv) when transmitting reference signals for synchronizing time from the reference standard of the units of time and<br>frequency of the Armed Forces of Ukraine (Kharkiv) in the observation interval of 30 days (with periodic daily switching<br>on the servers located in the ICEC of the Armed Forces of Ukraine) did not exceed 100 ns. With a continuous operating<br>mode (2 days), the RMS was not more than 65 ns. The research results make it possible to formulate basic requirements<br>for the composition, technical characteristics, functional capabilities and operating modes of the equipment of the military<br>consumer time synchronization system using the PTP and NTP protocols over packet data networks \u2013 Ethernet in order<br>to ensure its reliability and accuracy.<\/p>\n\n\n\n<div data-wp-interactive=\"core\/file\" class=\"wp-block-file\"><object data-wp-bind--hidden=\"!state.hasPdfPreview\" hidden class=\"wp-block-file__embed\" data=\"https:\/\/www.qrngua.website\/wp-content\/uploads\/2024\/12\/UMJ20201.pdf\" type=\"application\/pdf\" style=\"width:100%;height:600px\" aria-label=\"\u0412\u0441\u0442\u0430\u0432\u043a\u0430 UMJ20201\"><\/object><a id=\"wp-block-file--media-b3f5c954-46fa-41f7-93ba-1adc42db669b\" href=\"https:\/\/www.qrngua.website\/wp-content\/uploads\/2024\/12\/UMJ20201.pdf\">UMJ20201<\/a><a href=\"https:\/\/www.qrngua.website\/wp-content\/uploads\/2024\/12\/UMJ20201.pdf\" class=\"wp-block-file__button wp-element-button\" download aria-describedby=\"wp-block-file--media-b3f5c954-46fa-41f7-93ba-1adc42db669b\">\u0417\u0430\u0432\u0430\u043d\u0442\u0430\u0436\u0438\u0442\u0438<\/a><\/div>\n","protected":false},"excerpt":{"rendered":"<p>As part of the operation of the military segment of the Service of Universal Time and Reference Frequencies, theresults of the pilot operation of the subsystem for providing universal time for military consumers are presented, which isbuilt on the basis of the national measurement standard of time and frequency, the output standard of the Armed [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-235","post","type-post","status-publish","format-standard","hentry","category-1"],"_links":{"self":[{"href":"https:\/\/www.qrngua.website\/index.php?rest_route=\/wp\/v2\/posts\/235","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.qrngua.website\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.qrngua.website\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.qrngua.website\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.qrngua.website\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=235"}],"version-history":[{"count":2,"href":"https:\/\/www.qrngua.website\/index.php?rest_route=\/wp\/v2\/posts\/235\/revisions"}],"predecessor-version":[{"id":239,"href":"https:\/\/www.qrngua.website\/index.php?rest_route=\/wp\/v2\/posts\/235\/revisions\/239"}],"wp:attachment":[{"href":"https:\/\/www.qrngua.website\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=235"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.qrngua.website\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=235"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.qrngua.website\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=235"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}